High-performance skylights can be a functional and valuable addition to a commercial or industrial space. By bringing natural daylight indoors, they can help create a well-lit environment and reduce reliance on electric lighting when paired with appropriate lighting controls.
But skylights are not a one-size-fits-all building component. The right selection depends on the building, roof assembly, climate, performance requirements and daylighting goals.
Various factors go into selecting a commercial skylight. Choosing an appropriate product and installation detail helps support performance, manage maintenance needs and protect the integrity of the roof system.
Consider these nine factors when evaluating skylights for a commercial or industrial building.
The size, number and spacing of skylights affect both daylight distribution and heat transfer. Selection should account for the floor area, ceiling height, existing windows, interior layout and intended use of the space.
For commercial buildings, work with the design team to determine skylight area and placement using applicable energy codes and project-specific daylighting analysis. Residential sizing rules should not replace commercial design requirements.
Skylights come in different shapes and configurations, including rectangular, domed and tubular designs. The appropriate configuration depends on the roof structure, available space and the amount and distribution of daylight needed below.
Evaluate how the skylight distributes light as well as how it fits the roof. Glazing, diffusion, interior obstructions and ceiling geometry all influence the resulting daylight conditions.
Skylights can reduce electric lighting demand when daylight is sufficient and lighting controls dim or switch off fixtures. Overall energy performance also depends on heat gain, heat loss, climate and building operation.
When comparing products, review independently certified energy performance ratings from the National Fenestration Rating Council rating system, where applicable. Key measures include:
Insulated glazing, appropriate tints and low-emissivity coatings may help balance daylight with thermal performance. Evaluate these features as part of the building’s broader sustainability and energy goals.
Some skylights provide ventilation in addition to daylight. Operable models may help release warm air, while fixed skylights are designed to remain closed.
Confirm whether ventilation is needed and whether the selected product supports it. Coordinate any operable skylights with the building’s mechanical systems, controls and weather protection requirements.
The building’s climate zone influences the thermal performance required of a skylight. Colder climates may place greater emphasis on limiting heat loss, while warmer climates may require greater control of solar heat gain.
Review the applicable local energy code and project specifications. Select glazing, frames and curb details that address the building’s climate and condensation-control requirements.
Skylights and their attachment details must meet the project’s wind design requirements. These requirements depend on factors such as geographic location, building height, exposure and the skylight’s position on the roof.
In hurricane-prone areas, additional product approvals or impact-resistance requirements may apply. Confirm that the exact skylight model, curb and installation configuration meet the applicable requirements.
Hail exposure is another important selection factor. Evaluate the project location, owner requirements and insurer criteria when determining the necessary hail resistance.
Review test results and ratings for the specific product configuration. Glazing material, thickness and assembly design can affect impact performance, so a rating for one skylight configuration should not be assumed to apply to another.
A building’s insurance requirements may influence skylight selection. Where FM Approval is required, confirm the current approval for the specific product and installation configuration.
Ask for documentation addressing the performance requirements relevant to the project, including fire, hail and wind resistance. Approval of a product does not mean every installation of that product meets the building’s requirements.
The Elevate skylights page includes selection resources covering wind load, hail rating, climate zone, insurance and hurricane-zone considerations. Use these resources alongside current local codes and project specifications.
Before purchasing a skylight, review the applicable warranty, including the term, covered components, exclusions and installation requirements.
Warranty options vary by product and roof system. Confirm whether coverage applies to the skylight unit, installation or eligible roof system, and review the current requirements with an Elevate sales representative.
High-performance skylights can be a useful part of an overall daylighting strategy. Their value depends on selecting the right products, integrating them with the roof assembly and managing daylight, glare and heat transfer.
Elevate SunWave™ Prismatic Skylights are designed to bring diffused natural light into commercial spaces. As part of a coordinated daylighting strategy, skylights can help reduce dependence on electric lighting during daytime hours.
Explore Elevate skylight options and connect with your nearest Elevate sales representative for help evaluating products, technical requirements and daylighting strategies for your building.
Your response helps us make our online experience better to provide content that is specific to your role.
Thank you. Your response helps us make our online experience better to provide content that is specific to your role.